[Date Prev][Date Next][Date Index] MedFlight of Ohio - Non-injury incidentDate: 09/07/2007 14:25 EDT Program: MedFlight of Ohio 2827 W. Dublin Granville Rd Columbus, OH 43235 Type: AS350 B-2 Tail #: N350MV Operator/Vendor: OmniFlight Helicopters Inc. Weather: Clear. Not a factor Team: No injuries reported. No patient. Description: At ~1425 on 9/7 crew received a request for a scene response close to the base. Pilot okayed the flight and received the release number from the Operational Control Center at Omniflight. Crew responded to aircraft where they noted that the mechanic had placed the blade tie downs on the aircraft due to increasing winds coming up throughout the afternoon. Pilot proceeded to remove blade covers and handed them to the paramedic who took them inside the base. The pilot proceeded to start the aircraft and noted that he had not removed the tail rotor block. He immediately shut down the aircraft and aborted the response and placed the aircraft out of service pending inspection. A small mark was noted on one of the trim tabs and the tail rotor blades were subsequently replaced and aircraft was placed back in service. Source: Tom Allenstein, Chief Clinical Officer =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= The CONCERN network shares verified information to alert medical transport programs when an accident / incident has occurred. Please share the above information with your program staff. If you have further questions, please contact the CONCERN Coordinator, David Kearns at 800 525 3712 or email: coordinator@concern-network.org. Copyright 2007 ASTNA
|