[Date Prev][Date Next][Date Index] St. Mary's CareFlight - Non-injury incidentDate: 04/10/2008 mnt Program: St. Mary's CareFlight Grand Junction, Colorado Type: Bell 412EP Tail #: N412SM Operator/Vendor: PHI Weather: Clear. Not a factor Team: Pilot, Nurse, Paramedic. No injuries reported. No patient. Description: On initial start up for an interfacility transport a security guard witnessed a towel blow up through the rotor system. The security guard picked up the towel but failed to notify the crew of the incident. The crew was allowed to take off and fly away. Upon return the pilot was notified by the security supervisor of what had happen. The helicopter was taken out of service at that time and a thorough inspection was performed by the mechanic. No damage was discovered and the helicopter was returned to sevice. Additional Info: Security was informed of the seriousness of the incident. And it was explained that the guard on duty must inform the crew immediately of such an occurence. Additional training will be given to security personnel. Source: Mike Johnson Lead Flight Paramedic =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= The CONCERN network shares verified information to alert medical transport programs when an accident / incident has occurred. Please share the above information with your program staff. If you have further questions, please contact the CONCERN Coordinator, David Kearns at 800 525 3712 or email: coordinator@concern-network.org. Copyright 2007 ASTNA
|